Title: An ultrasound-actuated micropump that uses one-way membrane as Nozzle-diffuser
Authors: Chao, C
Cheng, CH 
Liu, Z
Yang, M 
Leung, WWF 
Keywords: Corner reflection
Multipath interference
Ultrasonic ranging
Issue Date: 2008
Source: Proceedings - IEEE Ultrasonics Symposium, 2008, 4803532, p. 521-524 How to cite?
Abstract: In this paper, we study a nozzle-diffuser micropump is actuated by ultrasound waves. The nozzle-diffuser is made a nanoporous one-way membrane. The micropump was by enclosing the nanoporous membrane into a PMMA chamber. Once immersed into ultrasonic water bath, the can continuously pump the water through the one-way . This device is ideal for future implantable drug system that can be remotely controlled by ultrasound .