Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/31178
Title: Liver fibrosis assessment using transient elastography guided with real-time b-mode ultrasound imaging
Authors: Zheng, YP 
Mak, TM
Huang, ZM
Cheung, CWJ
Zhou, YJ
He, JF
Keywords: Elasticity imaging
Liver fibrosis
Soft tissue
Transient elastography
Ultrasound
Issue Date: 2010
Publisher: Springer
Source: IFMBE Proceedings, 2010, v. 31 IFMBE, p. 1036-1039 How to cite?
Journal: IFMBE Proceedings 
Abstract: Liver fibrosis is a kind of chronic damage of the liver. The progression of liver fibrosis will result cirrhosis which is one of the top 10 causes of death in the western world. Recently, a device developed based on transient ultrasound elastography, named as Fibroscan, shows promising results with high accuracy and good reproducibility. However, this device does not provide visual guidance for the liver being tested during measurement. We aim to design and validate a transient elastography system with real-time B-mode imaging for liver fibrosis assessment. Our development is based on a conventional B-mode ultrasound scanner, which consists of a B-mode ultrasound probe fixed along the axis of a mechanical vibrator. The induced shear wave propagates through the liver tissue. During measurement, B-mode ultrasound imaging with a frame rate of 30 f/s is generated in real-time to view the morphological information of the tissue, and an A-mode ultrasound with a frame rate of 6000 f/s is generated to track the propagation of shear wave at a selected location. The propagation speed of the shear wave is related to the tissue stiffness and Young's modulus is calculated. The system was tested using a series of custom-made phantoms with different stiffness and the results were compared with those measured by Fibroscan. For phantom A1, the Young's modulus is 32.4 kPa and 35.4 kPa obtained by Fibroscan and our system, respectively. For phantom A2, the modulus is 15.9 kPa and 19.8 kPa, respectively. For the preliminary in vivo assessment, the Young's modulus of a normal male subject is 5.8 kPa and 7.5 kPa obtained by Fibroscan and our system, respectively. In summary, we have successfully developed a transient ultrasound elastography system with real-time B-mode imaging for the assessment of liver fibrosis.
Description: 6th World Congress of Biomechanics, WCB 2010 - In Conjunction with 14th International Conference on Biomedical Engineering, ICBME and 5th Asia Pacific Conference on Biomechanics, APBiomech, Singapore, 1-6 August 2010
URI: http://hdl.handle.net/10397/31178
ISBN: 9783540790389
ISSN: 1680-0737
DOI: 10.1007/978-3-642-14515-5_264
Appears in Collections:Conference Paper

Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page view(s)

47
Last Week
2
Last month
Checked on Sep 17, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.