Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/30070
Title: A knowledge-based computer-aided system for closed diaphyseal fracture reduction
Authors: Koo, TKK
Mak, AFT
Keywords: Closed fracture reduction
Computer-aided surgery
Diaphyseal fracture
External fixation
Issue Date: 2007
Publisher: Pergamon Press
Source: Clinical biomechanics, 2007, v. 22, no. 8, p. 884-893 How to cite?
Journal: Clinical biomechanics 
Abstract: Background: We recently developed an algorithm to perform closed fracture reduction using unilateral external fixator. Although its validity has been verified experimentally, the whole reduction process was not evaluated owing to the lack of a device that could facilitate its implementation in clinical practice. The objective of this study is to develop a prototype of such a system, and quantify its reduction accuracy. Methods: The system consists of a custom-made unilateral external device and a self-contained software package. The device features 7 one degree of freedom joints, each allows for continuous adjustments and is equipped with measurement components to facilitate accurate positioning. A CT-based method was developed, which facilitates virtual reduction and calculates the adjustment requirements that reduce a fracture deformity. The device was adjusted off-the-site and reattached back in place to guide the reduction of the fracture fragments. Reduction accuracy was evaluated using eight phantoms of different types, sides and fracture patterns by calculating the rotation about a screw axis and the displacement between the origins of the distal and proximal local coordinate systems after the reduction. Findings: The mean (SD) of the translational and rotational reduction errors were 1.73 (0.97) mm and 2.57° (1.36°), respectively, which demonstrated the accuracy and reliability of the system. Interpretation: The system allows surgeons to perform fracture reduction in an objective, efficient, and accurate manner yet minimize the radiation exposure and lessens the extent of tissue disruption around the fracture site during the reduction process.
URI: http://hdl.handle.net/10397/30070
ISSN: 0268-0033
EISSN: 1879-1271
DOI: 10.1016/j.clinbiomech.2007.05.005
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

9
Last Week
0
Last month
0
Citations as of Nov 18, 2017

WEB OF SCIENCETM
Citations

6
Last Week
0
Last month
0
Citations as of Nov 15, 2017

Page view(s)

43
Last Week
1
Last month
Checked on Nov 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.