Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/29900
Title: Application of switchable glazing to high-rise residential buildings in Hong Kong
Authors: Yik, F
Bojic, M
Keywords: Building envelope
Cooling
Switchable glazing
Issue Date: 2006
Publisher: Elsevier
Source: Energy and buildings, 2006, v. 38, no. 5, p. 463-471 How to cite?
Journal: Energy and buildings 
Abstract: For typical high-rise residential building in Hong Kong, we evaluated the impact of using switchable glazing on energy use for space cooling. By using software EnergyPlus, it was found that application of switchable glazing would lead to a reduction in annual cooling electricity consumption by up to 6.6% where the actual amount depends on existence of overhangs, orientation of building wings, types and locations of rooms. Energy saving by this magnitude, however, cannot justify use of switchable glazing in residential buildings in Hong Kong, mainly because of the high glazing cost.
URI: http://hdl.handle.net/10397/29900
ISSN: 0378-7788
EISSN: 1872-6178
DOI: 10.1016/j.enbuild.2005.08.006
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query