Title: Finite element analysis of 1 MW high speed wound-rotor synchronous machine
Authors: Liu, H
Xu, L
Shangguan, M
Fu, WN 
Keywords: Finite-element method (FEM)
High speed
Magnetic fields
Wound-rotor synchronous machine (WRSM)
Issue Date: 2012
Publisher: Institute of Electrical and Electronics Engineers
Source: IEEE transactions on magnetics, 2012, v. 48, no. 11, 6332554, p. 4650-4653 How to cite?
Journal: IEEE transactions on magnetics 
Abstract: A 1000 kW/19200 rpm wound-rotor synchronous machine has been designed as a draft based on 2-D transient finite-element method (FEM). The magnetic fields distribution, the iron losses, the electromagnetic torque and the terminal characteristics of the prototype machine are investigated in this paper by using 2-D finite element analysis. The d-axis inductance L d and the q-axis inductance L q of the sample machine are predicted in analytical models. All studies indicate that the wound-rotor synchronous machine is potential to apply in high speed generator or motor application.
URI: http://hdl.handle.net/10397/29172
ISSN: 0018-9464
EISSN: 1941-0069
DOI: 10.1109/TMAG.2012.2198050
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

8
Last Week
0
Last month
0
Citations as of Oct 11, 2017

WEB OF SCIENCETM
Citations

7
Last Week
0
Last month
0
Citations as of Oct 21, 2017

Page view(s)

39
Last Week
1
Last month
Checked on Oct 16, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.