Title: Locating room air-conditioners at floor level for energy saving in residential buildings
Authors: Gao, CF
Lee, WL 
Chen, H
Keywords: Air-conditioner
Computational fluid dynamics
Energy saving
Floor-based
Residential
Issue Date: 2009
Publisher: Pergamon Press
Source: Energy conversion and management, 2009, v. 50, no. 8, p. 2009-2019 How to cite?
Journal: Energy conversion and management 
Abstract: Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential buildings is therefore recommended.
URI: http://hdl.handle.net/10397/28918
ISSN: 0196-8904
DOI: 10.1016/j.enconman.2009.04.009
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

14
Last Week
0
Last month
0
Citations as of May 21, 2017

WEB OF SCIENCETM
Citations

10
Last Week
0
Last month
0
Citations as of May 20, 2017

Page view(s)

37
Last Week
0
Last month
Checked on May 21, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.