Title: A statistical method for selection of sequences of coincident weather parameters for design cooling load calculations
Authors: Chen, T
Yu, Z
Keywords: Building
Peak cooling load
Design weather data
Air-conditioning systems design
Z-Transfer function
Issue Date: 2009
Publisher: Pergamon Press
Source: Energy conversion and management, 2009, v. 50, no. 3, p. 813-821 How to cite?
Journal: Energy conversion and management 
Abstract: Current design weather data recommended by ASHRAE and CIBSE may result in overestimated peak cooling loads. This is because solar radiation, and outdoor dry-bulb and wet-bulb temperatures selected for design conditions do not occur coincidently. Hence, the data cannot reflect the joint statistical distribution of these three weather parameters. Moreover, the peak cooling load largely depends on the characteristics of both weather and buildings. A statistical method has been developed for the rational selection of sequences of coincident design weather parameters in order to properly determine peak cooling loads. Overall periodic transfer factors responding to different periodic weather heat sources are first derived based on the radiant time series (RTS) method. This allows us to utilize the available thermal and optical properties of a building without the need for tedious regenerating these data. The periodic transfer factors are then equivalently transformed to z-transfer coefficients. The model has been applied to hourly weather records of 25 years in Hong Kong to generate the hourly cooling loads of buildings with any thermal lag. Sequences of coincident design solar irradiance, dry-bulb and wet-bulb temperatures have been rationally determined through statistical analysis of the computed cooling loads. Results indicate that horizontal solar irradiance computed with the method recommended by ASHRAE is always higher, 4–20%, than the measured value in different months. The peak cooling load resulted from the traditional design weather data is always much higher, 12–50%, than the results from the new design weather data. An unreasonably oversized air-conditioning system would cause high initial cost and unnecessary significant use in embodied energy. It would also deteriorate the part-load energy efficiency and the system management effectiveness.
URI: http://hdl.handle.net/10397/27244
ISSN: 0196-8904
EISSN: 1879-2227
DOI: 10.1016/j.enconman.2008.09.021
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

3
Citations as of Apr 11, 2016

WEB OF SCIENCETM
Citations

3
Last Week
0
Last month
0
Citations as of Aug 15, 2017

Page view(s)

34
Last Week
1
Last month
Checked on Aug 13, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.