Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/25730
DC FieldValueLanguage
dc.contributorDepartment of Civil and Environmental Engineering-
dc.creatorXu, YL-
dc.creatorYang, ZC-
dc.creatorChen, J-
dc.creatorLiu, HJ-
dc.creatorChen, J-
dc.date.accessioned2014-12-30T08:36:29Z-
dc.date.available2014-12-30T08:36:29Z-
dc.identifier.issn0141-0296-
dc.identifier.urihttp://hdl.handle.net/10397/25730-
dc.language.isoenen_US
dc.publisherPergamon Pressen_US
dc.subjectActively controlled platformen_US
dc.subjectHigh tech equipmenten_US
dc.subjectMicrovibrationen_US
dc.subjectTraffic-induced ground motionen_US
dc.titleMicrovibration control platform for high technology facilities subject to traffic-induced ground motionen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage1069-
dc.identifier.epage1082-
dc.identifier.volume25-
dc.identifier.issue8-
dc.identifier.doi10.1016/S0141-0296(03)00049-X-
dcterms.abstractThis paper investigates the possibility of using a microvibration control platform to isolate a batch of high tech equipment from the floor of a building subject to nearby traffic-induced ground motion. The governing equation of motion of the coupled platform-building system is derived in the absolute coordinate to facilitate the feedback control and performance evaluation of the platform based on the BBN vibration criteria with the absolute velocity being targeted. A hybrid control system composed of passive mounts and active hydraulic actuators with a sub-optimal control algorithm is designed to actively control the platform. Hydraulic actuator dynamics are also considered in the modelling of the control system to avoid possible instability of the platform. The performance of actively controlled platform is assessed through comparisons with the cases of the building without control, the building with passively controlled platform, and the building with passive base isolator. Simulation results indicate that passively controlled platform and passive base isolator can be effective in reducing microvibration of high tech equipment if their parameters are properly selected. The actively controlled platform is superior to the passively controlled platform and passive base isolator because of its high performance and robustness.-
dcterms.bibliographicCitationEngineering structures, 2003, v. 25, no. 8, p. 1069-1082-
dcterms.isPartOfEngineering structures-
dcterms.issued2003-
dc.identifier.scopus2-s2.0-0038206581-
dc.identifier.eissn1873-7323-
dc.identifier.rosgroupidr13464-
dc.description.ros2002-2003 > Academic research: refereed > Publication in refereed journal-
Appears in Collections:Journal/Magazine Article
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

SCOPUSTM   
Citations

28
Last Week
0
Last month
1
Citations as of Aug 28, 2020

WEB OF SCIENCETM
Citations

22
Last Week
0
Last month
1
Citations as of Oct 30, 2020

Page view(s)

148
Last Week
0
Last month
Citations as of Oct 26, 2020

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.