Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/2524
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Health Technology and Informatics-
dc.creatorHuang, YP-
dc.creatorSaarakkala, S-
dc.creatorToyras, J-
dc.creatorWang, LK-
dc.creatorJurvelin, JS-
dc.creatorZheng, YP-
dc.date.accessioned2014-12-11T08:22:57Z-
dc.date.available2014-12-11T08:22:57Z-
dc.identifier.issn0031-9155-
dc.identifier.urihttp://hdl.handle.net/10397/2524-
dc.language.isoenen_US
dc.publisherIOP Publishingen_US
dc.rights© 2011 Institute of Physics and Engineering in Medicine. The online abstract of the journal is located at: http://iopscience.iop.org/0031-9155/56/2/013en_US
dc.subjectOptics, quantum optics and lasersen_US
dc.subjectBiological physicsen_US
dc.subjectMedical physicsen_US
dc.titleEffects of optical beam angle on quantitative optical coherence tomography (OCT) in normal and surface degenerated bovine articular cartilageen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage491-
dc.identifier.epage509-
dc.identifier.volume56-
dc.identifier.issue2-
dc.identifier.doi10.1088/0031-9155/56/2/013-
dcterms.abstractQuantitative measurement of articular cartilage using optical coherence tomography (OCT) is a potential approach for diagnosing the early degeneration of cartilage and assessing the quality of its repair. However, a non-perpendicular angle of the incident optical beam with respect to the tissue surface may cause uncertainty to the quantitative analysis, and therefore, significantly affect the reliability of measurement. This non-perpendicularity was systematically investigated in the current study using bovine articular cartilage with and without mechanical degradation. Ten fresh osteochondral disks were quantitatively measured before and after artificially induced surface degradation by mechanical grinding. The following quantitative OCT parameters were determined with a precise control of the surface inclination up to an angle of 10° using a step of 2°: optical reflection coefficient (ORC), variation of surface reflection (VSR) along the surface profile, optical roughness index (ORI) and optical backscattering (OBS). It was found that non-perpendicularity caused systematic changes to all of the parameters. ORC was the most sensitive and OBS the most insensitive to the inclination angle. At the optimal perpendicular angle, all parameters could detect significant changes after surface degradation (p < 0.01), except OBS (p > 0.05). Nonsignificant change of OBS after surface degradation was expected since OBS reflected properties of the internal cartilage tissue and was not affected by the superficial mechanical degradation. As a conclusion, quantitative OCT parameters are diagnostically potential for characterizing the cartilage degeneration. However, efforts through a better controlled operation or corrections based on computational compensation mechanism should be made to minimize the effects of non-perpendicularity of the incident optical beam when clinical use of quantitative OCT is considered for assessing the articular cartilage.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationPhysics in medicine and biology, 21 Jan. 2011, v. 56, no. 2, p. 491-509-
dcterms.isPartOfPhysics in medicine and biology-
dcterms.issued2011-01-21-
dc.identifier.isiWOS:000285743000015-
dc.identifier.scopus2-s2.0-79551679362-
dc.identifier.rosgroupidr55998-
dc.description.ros2010-2011 > Academic research: refereed > Publication in refereed journal-
dc.description.oaAccepted Manuscripten_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
2010 Phys Med Biol Effects of optical beam angle on quantit.pdfPre-published version931.23 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

131
Last Week
1
Last month
Citations as of Apr 14, 2024

Downloads

213
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

14
Last Week
0
Last month
0
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

12
Last Week
0
Last month
0
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.