Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/24379
Title: Analysis of bolted moment connections in cold-formed steel beam-column sub-frames
Authors: Yu, WK
Chung, KF 
Wong, MF
Keywords: Bolted moment connections
Cold-formed steel
Combined bending and shear
Connection flexibility
Non-linear analysis
Semi-rigid joints
Issue Date: 2005
Publisher: Elsevier
Source: Journal of constructional steel research, 2005, v. 61, no. 9, p. 1332-1352 How to cite?
Journal: Journal of constructional steel research 
Abstract: An extensive experimental investigation on bolted moment connections between cold-formed steel sections was carried out, and a total of 16 internal and external beam-column sub-frames with various connection configurations were tested under lateral loads. It is found that for those six beam-column sub-frames with large bolt pitches and thick gusset plates in the connections, flexural failure of connected sections is always critical. The moment resistances of the connections attain at least 85% of the moment capacities of the connected sections. This paper presents a theoretical investigation for predicting the structural behaviour of bolted moment connections between cold-formed steel sections. An analysis and design method for internal force distribution of the connections is presented, and hence a set of design rules for section failure of connected sections under combined bending and shear is proposed. Moreover, a non-linear finite element model of the beam-column sub-frames incorporating the effect of semi-rigid joints is also presented. On the basis of the measured moment joint rotation curves of the bolted moment connections, the overall lateral load-deflection curves of the sub-frames are predicted, and they are found to follow closely the curves obtained from tests. Furthermore, a semi-empirical formula for flexibility prediction of the bolted moment connections is also proposed after careful calibration against test data. It is demonstrated that the proposed rules are highly effective for predicting the structural performance of cold-formed steel frames with bolted moment connections. Hence, structural engineers are encouraged to design and build cold-formed steel structures with bolted moment connections to achieve practical and efficient construction.
URI: http://hdl.handle.net/10397/24379
ISSN: 0143-974X
EISSN: 1873-5983
DOI: 10.1016/j.jcsr.2005.03.001
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

36
Last Week
0
Last month
0
Citations as of Aug 24, 2017

WEB OF SCIENCETM
Citations

25
Last Week
0
Last month
Citations as of Aug 21, 2017

Page view(s)

57
Last Week
0
Last month
Checked on Aug 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.