Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/23724
Title: Real-time measurement of patellofemoral kinematics in asymptomatic subjects
Authors: Laprade, J
Lee, R
Keywords: Kinematics
Magnetic tracking
Patella
Three-dimensional
Issue Date: 2005
Publisher: Elsevier Science Bv
Source: Knee, 2005, v. 12, no. 1, p. 63-72 How to cite?
Journal: Knee 
Abstract: The aims of this study were to determine whether patellofemoral kinematics in the anteroposterior (AP), mediolateral (ML) and proximal-distal (PD) directions could be measured in real time with high repeatability using a three-dimensional magnetic tracking system, and to evaluate the symmetry between sides. Data was collected from both knees of 40 asymptomatic subjects while performing knee flexion from 0° to 60°. Measurement of patellar displacement along the three anatomical axes (AP, ML, and PD) with respect to an anatomical coordinate system was collected using the Fastrak system. Data from three trials of each knee was plotted against knee angle and the repeatability of the data determined by examining the similarity of the movement-time curves. Symmetry was determined for maximal displacement and kinematic pattern, and a paired t-test performed to evaluate differences between sides. The data was found to be highly repeatable with mean r values for the three directions over 0.85 for both sides. The pattern of patellar displacement and maximal displacement was comparable to that reported in the literature. Results of paired t-test revealed no significant differences between the knees when comparing maximal displacement in any direction (p>0.05). Overall, there was a highly symmetrical kinematic pattern for ML and PD displacement and a small degree of asymmetry for AP displacement. However, wide variations among the subjects were noted between the left and right patellae in all directions. The results of this study have demonstrated that the use of magnetic tracking sensors provides repeatable and relevant three-dimensional kinematic data of in vivo patella tracking from 0° to 60° of knee flexion.
URI: http://hdl.handle.net/10397/23724
ISSN: 0968-0160
DOI: 10.1016/j.knee.2004.02.004
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

41
Last Week
0
Last month
0
Citations as of Nov 18, 2017

WEB OF SCIENCETM
Citations

31
Last Week
0
Last month
0
Citations as of Nov 15, 2017

Page view(s)

41
Last Week
2
Last month
Checked on Nov 19, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.