Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/23374
Title: Several key problems in tunnel construction monitoring with FBG
Authors: Wei, GQ
Shi, B
Hu, S
Li, K
Yin, JH 
Keywords: FBG
Sensor sealing
Spraying concrete
Temperature compensation
Tunnel monitoring
Issue Date: 2009
Publisher: 南京水利科學硏究院
Source: 岩土工程學報 (Chinese journal of geotechnical engineering), 2009, v. 31, no. 4, p. 571-576 How to cite?
Journal: 岩土工程學報 (Chinese journal of geotechnical engineering) 
Abstract: Fiber Bragg grating (FBG) sensor has a number of advantages such as high sensitivity, multiplexing capabilities, fast response, resistance to corrosion, and immunity to electromagnetic noise and radio frequency interference, and has been widely applied in engineering monitoring. The environment of tunnel construction site is usually very severe and harsh, whereas the unprotected FBG sensor is very vulnerable and sensitive to its surroundings. Therefore there are still some key problems to be solved when the FBG sensor is used in tunnel construction monitoring. Some key problems such as the protection of FBG sensor, temperature compensation and monitoring system integration for tunnel construction are discussed and analyzed through a practical engineering case. It is indicate that the survival rate of FBG sensor can be greatly raised via proper sealing and protection, and the real-time monitoring for the strain and stress of the arch and supporting bar and temperature of tunnel structure during the blasting excavating and concrete spraying of tunnel is feasible.
URI: http://hdl.handle.net/10397/23374
ISSN: 1000-4548
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

9
Last Week
0
Last month
Citations as of Oct 12, 2018

Page view(s)

60
Last Week
0
Last month
Citations as of Oct 15, 2018

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.