Title: The effect of beam tube potential variation on gonad dose to patients during chest radiography investigated using high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeters
Authors: Fung, KKL 
Gilboy, WB
Issue Date: 2001
Publisher: British Institute of Radiology
Source: British journal of radiology, 2001, v. 74, no. 880, p. 358-367 How to cite?
Journal: British journal of radiology 
Abstract: Optimization of X-ray beam tube potential (kVp) in radiological examinations can minimize patient dose. This research aims to investigate the effect of tube potential variation on gonad doses to patients during posteroanterior (PA) chest radiography examinations. This study was carried out using a Toshiba general purpose X-ray unit and a Rando phantom. Dose measuring equipment included an ion chamber system, a dose-area product (DAP) meter and a thermoluminescent dosemeter (TLD) reader system with high sensitivity TLD pellets of LiF:Mg,Cu,P for low level gonad dose measurement. PA chest exposures of the phantom to produce a constant exit dose were made using a standard low tube potential (range 60-100 kVp) non-grid technique and a high tube potential (range 95-150 kVp) grid technique. Entrance surface doses (ESDs) and DAPs were also included in the measurements. Effective doses (EDs) were computed from ESD and DAP measurements using NRPB-SR262 and Xdose software. Results show that with the low tube potential technique both ovary dose and testes dose increase with increasing tube potential; statistically significant correlations of r=0.994 (p=0.0006) and r=0.998 (p=0.001), respectively, were found. For both organs, doses increase at a rate of approximately 2% per kVp. With the high tube potential technique there is insignificant correlation between gonad doses and tube potential. When comparing patient doses from typical exposures made at 70 kVp (low tube potential non-grid technique) with doses from exposures made at 120 kVp (high tube potential grid technique), the high tube potential technique delivers significantly higher values for ESD, and ovary, testes and effective doses by factors of 1.7, 5.2, 5.5 and 2.7, respectively.
URI: http://hdl.handle.net/10397/22029
ISSN: 0007-1285
EISSN: 1748-880X
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

29
Last Week
0
Last month
0
Citations as of Sep 11, 2017

WEB OF SCIENCETM
Citations

20
Last Week
1
Last month
0
Citations as of Sep 23, 2017

Page view(s)

46
Last Week
3
Last month
Checked on Sep 24, 2017

Google ScholarTM

Check



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.