Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/21660
Title: Effect of instrument rotation on handheld keratometry
Authors: Lam, AKC 
Chan, R
Chiu, R
Issue Date: 2004
Source: Journal of cataract and refractive surgery, 2004, v. 30, no. 12, p. 2590-2594 How to cite?
Journal: Journal of Cataract and Refractive Surgery 
Abstract: To study the effect of instrument rotation on handheld automated keratometry. Department of Optometry and Radiography, The Hong Kong Polytechnic University, Hong Kong SAR, China. In 33 recruited subjects, corneal curvature in 1 eye (randomly selected) was measured using a Medmont topographic keratometer and a Nidek handheld keratometer. In handheld keratometry, measurements were obtained holding the instrument in the upright position and rotating it anticlockwise 5 degrees, 10 degrees, and 15 degrees and then clockwise 5 degrees, 10 degrees, and 15 degrees. The sequence of measurements was randomly assigned. The steepest and flattest corneal curvatures as well as the axis along the flattest meridian were compared in different conditions. The corneal power was converted to vector representation (M, J 0, J 45) for a second comparison. There was a significant difference in the steepest and flattest curvatures in different conditions (repeated-measures analysis of variation, P<.05). However, the mean difference between handheld and topographic keratometry was approximately 0.25 diopter (D) for the steepest curvature and 0.05 D for the flattest curvature regardless of the direction and amount of rotation. The intraclass correlation coefficients were nearly 1, which indicated good clinical reliability. The mean difference in axis determination followed the direction and amount of rotation. With vector representation, the difference between the devices increased with the amount of rotation, especially J 0 and J 45. Handheld keratometry was in agreement with topographic keratometry. However, practitioners should adjust the axis manually according to the direction and amount of rotation. The difference between handheld and topographic keratometry increased with the rotational effect, which was seen with vector representation. Practitioners are advised to use the handheld keratometer in the upright position.
URI: http://hdl.handle.net/10397/21660
ISSN: 0886-3350
DOI: 10.1016/j.jcrs.2004.04.069
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

8
Last Week
0
Last month
0
Citations as of Nov 18, 2017

WEB OF SCIENCETM
Citations

6
Last Week
0
Last month
Citations as of Nov 15, 2017

Page view(s)

47
Last Week
1
Last month
Checked on Nov 12, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.