Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/20424
Title: Flame stretching in a room model with natural vent
Authors: Chow, WK 
Han, SS
Gao, Y
Dong, H
Huo, Y
Zhang, YM
Li, SS
Issue Date: 2009
Source: Proceedings of the ASME Summer Heat Transfer Conference 2009, HT2009, 2009, v. 3, p. 27-30 How to cite?
Abstract: Flame stretching in a room with a ceiling vent will be discussed in this short note. A real-scale model was constructed with a gasoline pool fire placed inside. Another pool fire of the same size and amount of fuel was burnt outside the model. Different pool sizes of diameters 0.07 m, 0.08 m, 0.11 m, 0.16 m and 0.2 m were set up. Volume of gasoline varied from 30 ml to 500 ml to give different burning durations. The flame lengths of the two fires were measured and compared. It is observed that the flame length of the pool fire inside the room was over 20% higher than that outside at the later stage of the fire.
Description: 2009 ASME Summer Heat Transfer Conference, HT2009, San Francisco, CA, 19-23 July 2009
URI: http://hdl.handle.net/10397/20424
ISBN: 9780791843581
DOI: 10.1115/HT2009-88084