Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/20224
Title: Practice of orthokeratology by a group of contact lens practitioners in Hong Kong Part 2. Orthokeratology lenses
Authors: Cho, P 
Cheung, SW
Edwards, MH
Keywords: Hong Kong
Lens design
Orthokeratology
Survey
Issue Date: 2003
Publisher: Wiley-Blackwell
Source: Clinical and experimental optometry, 2003, v. 86, no. 1, p. 42-46 How to cite?
Journal: Clinical and experimental optometry 
Abstract: Purpose: The aim of the study was to provide information about the characteristics of three main types of orthokeratology (ortho-k) lenses used in Hong Kong and to report on their performance based on the clinical impressions of a group of ortho-k practitioners. Method: Twelve ortho-k practitioners were interviewed between 1 March and 30 June 2001. Results: Most ortho-k lenses were ordered from three manufacturers: DreimLens, Fargo and Contex. The median maximum myopia reduction reported for DreimLens, Contex and Fargo lenses were 6.25 D, 6.00 D and 4.50 D respectively. The time to reduce myopia by up to 4.00 D could be up to three weeks for Contex and DreimLens and up to four weeks for Fargo. For reduction of myopia by up to 4.00 D, the treatment usually required only one or two lenses per eye for all three types of lenses. The incidence of lens binding and lens tightening after achieving the optimal reduction was reported to be higher with the DreimLens design. Good centration, less lens binding, relatively lower incidence of complications and lens tightening after achieving the optimal reduction were reported with the Fargo lenses. Conclusions: DreimLens tended to be more effective for myopia reduction. However, some practitioners were concerned with the aggressiveness of myopia reduction using this lens design and the higher potential for ocular complications. Selection of the lens design is dependent on various factors, in particular, practitioners need to be comfortable with the design they choose and to consider the needs of their patients and the final goal of the treatment.
URI: http://hdl.handle.net/10397/20224
ISSN: 0816-4622
EISSN: 1444-0938
DOI: 10.1111/j.1444-0938.2003.tb03056.x
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

11
Last Week
0
Last month
1
Citations as of Aug 14, 2017

Page view(s)

35
Last Week
1
Last month
Checked on Aug 13, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.