Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/19905
Title: Effects of different sonic access tube materials on the signal strength of ultrasonic waves in the cross-hole sonic logging technique
Authors: Chan, FWY
Tsang, SWF 
Keywords: Cross-hole sonic logging (CSL)
Foundation testing
Polyvinyl chloride (PVC)
Sonic access tubes
Steel
Ultrasonic evaluation
Issue Date: 2005
Publisher: Hong Kong Institution of Engineers
Source: HKIE transactions, 2005, v. 12, no. 2, p. 1-7 How to cite?
Journal: HKIE transactions 
Abstract: The Cross-hole Sonic Logging (CSL) technique is one of the most effective quality assurance methods for testing foundations in terms of assessing the homogeneity and integrity of in-situ concrete foundation elements. This paper aims to study the effects of sonic access tube materials (such as polyvinyl chloride (PVC) and steel) on the signal strength of ultrasonic waves when carrying out a CSL test. This aim was achieved by the use of an in-house developed multi-channel ultrasonic data acquisition prototype, referred to as the 'Multiple Referencing System' (MRS). The prototype was developed based on National Instruments (NI) hardware in a LabVIEW (Laboratory Virtual Instrument Engineering Workbench) environment. It was designed for pre-programmed data acquisition, processing and visualising. With the development of the in-house developed prototype MRS, the transmission velocity and signal strength of the acquired waveforms were determined by the use of different sonic access tubes. According to the experimental results, PVC tubes produce a lower attenuation than steel tubes due to a smaller difference in acoustic impedance between PVC and the testing medium. For each material, the signal strength increases with increasing sonic access tube diameter due to the effect of a curved surface of the walls of sonic access tubes. Sonic profiles with unclear and fuzzy successions of white and black lines may be obtained by the use of a larger-diameter (ie 150 mm diameter) sonic access tube, even though no defect is presented inside foundation concrete elements, as the probes can move around inside the tube. Inside sonic access tubes with a diameter more than twice the diameter of the probes, the probes should befitted with centralisers to prevent undue movement during measurement.
URI: http://hdl.handle.net/10397/19905
ISSN: 1023-697X
EISSN: 2326-3733
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page view(s)

51
Last Week
1
Last month
Checked on Oct 22, 2017

Google ScholarTM

Check



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.