Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/19515
Title: The outdoor air ventilation rate in high-rise residences employing room air conditioners
Authors: Lin, Z
Deng, S 
Keywords: CO2 level
Residences
Room air conditioner
Sleeping environment
Ventilation
Issue Date: 2003
Publisher: Pergamon-Elsevier Science Ltd
Source: Building and environment, 2003, v. 38, no. 12, p. 1389-1399 How to cite?
Journal: Building and Environment 
Abstract: Ventilation is important because it affects indoor environmental conditions, including air pollutant concentrations that may modify the health of the occupants of a building, or their perceptions and comfort. This paper reports, first of all, on field studies monitoring indoor overnight CO2 levels and outdoor ventilation rates in bedrooms employing room air conditioners (RACs), so the current situation of ventilation in actual high-rise residential buildings in Hong Kong can be appreciated. This is followed by a report of the results of laboratory experiments where two typical RACs were used in an examination of outdoor air ventilation characteristics in rooms employing RACs. The results of field studies showed that the outdoor ventilation rates in the measured bedrooms equipped with RACs in high-rise residential buildings in Hong Kong could not meet the ventilation requirement specified in the ASHRAE standard 62-2001 even if there was only one occupant in a bedroom. Although the use ofa window-type air conditioner (WRAC) may provide a higher outdoor ventilation rate than the use of a split-type air conditioner (SARC), this may be ascribed to the fact there is more natural infiltration when a WRAC is used. The ventilation damper currently available in a WRAC does not significantly affect the outdoor ventilation rate. Therefore, such a damper cannot be expected to provide the ventilation rate as required by a ventilation code and its intended function of controlling ventilation is limited. In addition, the air exhausted from indoors to outdoors through the ventilation outlet in a WRAC is air that has just been cooled by the cooling coil (evaporator). This is unreasonable, because exhausting just-cooled and dehumidified air is a waste of energy. Therefore, an improved design for a WRAC has been suggested. Finally, the outdoor ventilation requirement for bedrooms at nighttime, when occupants are asleep, is discussed. A new ventilation rate of 3.0 l/s per person for the sleeping environment in high-rise residential buildings is proposed.
URI: http://hdl.handle.net/10397/19515
ISSN: 0360-1323
DOI: 10.1016/j.buildenv.2003.07.001
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

20
Last Week
0
Last month
0
Citations as of Apr 25, 2017

WEB OF SCIENCETM
Citations

14
Last Week
0
Last month
1
Citations as of Apr 18, 2017

Page view(s)

23
Last Week
0
Last month
Checked on Apr 23, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.