Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/18802
Title: The effect of axial length on ocular blood flow assessment in anisometropes
Authors: Lam, AKC 
Chan, ST
Chan, B
Chan, H 
Keywords: Axial length
Colour doppler ultrasonography
End diastolic velocity
Peak systolic velocity
Pulsatile ocular blood flow
Issue Date: 2003
Publisher: Wiley-Blackwell
Source: Ophthalmic and physiological optics, 2003, v. 23, no. 4, p. 315-320 How to cite?
Journal: Ophthalmic and physiological optics 
Abstract: Background: Pulsatile ocular blood flow (POBF) assessment measures the choroidal circulation and therefore provides data with diagnostic value in certain ocular diseases, such as glaucoma. The technique assumes a constant pressure-volume relationship. The current study investigated the effect of axial length on POBF from subjects with axial anisometropia. Ocular blood supply in the ophthalmic artery was also determined using colour Doppler ultrasonography. Methods: Thirty-one normal, anisometropic subjects were recruited, whose ages ranged from 20 to 34 years. They had axial anisometropia (expressed by spherical equivalent) of at least 2 D. After Goldmann tonometry, the POBF of each eye was measured in a supine posture by one examiner, followed by a measurement of the blood flow velocity in the ophthalmic artery using colour Doppler ultrasonography in the same posture by another examiner. There was a 10 min rest between the two techniques. All the measurements were made at around the same time to eliminate any effect from diurnal variation. Results: The mean anisometropia (expressed by spherical equivalent) was 3.89 ± 1.96 D and the mean inter-ocular axial length difference was 1.49 ± 1.00 mm. The anisometropia and axial length were significantly different between the two eyes (paired t-tests: p < 0.001). However, the intraocular pressure was similar between the two eyes (paired t-test: p = 0.41). The POBF was significantly lower in the eye with the longer axial length (459.3 μL min -1) than the fellow eye (590.8 μL min -1), paired t-test: p < 0.001. The pulse amplitude was also significantly lower in the eye with the longer axial length (1.61 mmHg) than the fellow eye (1.89 mmHg), paired t-test: p < 0.001. However, the blood flow velocity from colour Doppler ultrasonography did not demonstrate any significant difference between the two eyes (paired t-test: p > 0.05). Conclusions: The POBF and pulse amplitude were found to be reduced in the eye with the longer axial length but colour Doppler ultrasonography did not show any significant difference. This suggests that a new pressure-volume relation should be considered in deriving POBF. Practitioners should measure the axial length in POBF assessment.
URI: http://hdl.handle.net/10397/18802
ISSN: 0275-5408
EISSN: 1475-1313
DOI: 10.1046/j.1475-1313.2003.00122.x
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

15
Last Week
0
Last month
0
Citations as of Aug 13, 2017

WEB OF SCIENCETM
Citations

12
Last Week
0
Last month
0
Citations as of Aug 20, 2017

Page view(s)

41
Last Week
0
Last month
Checked on Aug 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.