Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/16698
Title: Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses
Authors: Boone, DA
Kobayashi, T
Chou, TG
Arabian, AK
Coleman, KL
Orendurff, MS
Zhang, M 
Keywords: Alignment
Ankle
Diabetes
Osteoarthritis
Prosthesis
Issue Date: 2013
Publisher: Elsevier
Source: Gait and posture, 2013, v. 37, no. 4, p. 620-626 How to cite?
Journal: Gait and posture 
Abstract: Alignment - the process and measured orientation of the prosthetic socket relative to the foot - is important for proper function of a transtibial prosthesis. Prosthetic alignment is performed by prosthetists using visual gait observation and amputees' feedback. The aim of this study was to investigate the effect of transtibial prosthesis malalignment on the moments measured at the base of the socket: the socket reaction moments. Eleven subjects with transtibial amputation were recruited from the community. An instrumented prosthesis alignment component was used to measure socket reaction moments during ambulation under 17 alignment conditions, including nominally aligned using conventional clinical methods, and angle perturbations of 3° and 6° (flexion, extension, abduction, and adduction) and translation perturbations of 5. mm and 10. mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. Coronal alignment perturbations caused systematic changes in the coronal socket reaction moments. All angle and translation perturbations revealed statistically significant differences on coronal socket reaction moments compared to the nominal alignment at 30% and 75% of stance phase (. P<. 0.05). The effect of sagittal alignment perturbations on sagittal socket reaction moments was not as responsive as that of the coronal perturbations. The sagittal angle and translation perturbations of the socket led to statistically significant changes in minimum moment, maximum moment, and moments at 45% of stance phase in the sagittal plane. Therefore, malalignment affected the socket reaction moments in amputees with transtibial prostheses.
URI: http://hdl.handle.net/10397/16698
ISSN: 0966-6362
EISSN: 1879-2219
DOI: 10.1016/j.gaitpost.2012.10.002
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

25
Last Week
0
Last month
0
Citations as of Aug 13, 2017

WEB OF SCIENCETM
Citations

21
Last Week
0
Last month
0
Citations as of Aug 12, 2017

Page view(s)

31
Last Week
2
Last month
Checked on Aug 13, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.