Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/1662
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorInstitute of Textiles and Clothing-
dc.contributorDepartment of Electrical Engineering-
dc.contributorDepartment of Applied Physics-
dc.creatorCheng, KWE-
dc.creatorLu, Y-
dc.creatorChan, KWK-
dc.creatorKwok, YL-
dc.creatorKwok, KW-
dc.creatorKwok, KF-
dc.creatorXue, X-
dc.date.accessioned2014-12-11T08:26:37Z-
dc.date.available2014-12-11T08:26:37Z-
dc.identifier.isbn1-4244-0320-0-
dc.identifier.urihttp://hdl.handle.net/10397/1662-
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.rights© 2006 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.en_US
dc.rightsThis material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.en_US
dc.subjectInductanceen_US
dc.subjectLeakage currentsen_US
dc.subjectPower convertersen_US
dc.titleLeakage field modeling of spiral winding transformer for contactless power convertersen_US
dc.typeConference Paperen_US
dc.description.otherinformationAuthor name used in this publication: K. W. E. Chengen_US
dc.description.otherinformationAuthor name used in this publication: Y. Luen_US
dc.description.otherinformationAuthor name used in this publication: K. W. Chanen_US
dc.description.otherinformationAuthor name used in this publication: Y. L. Kwoken_US
dc.description.otherinformationAuthor name used in this publication: K. W. Kwoken_US
dc.description.otherinformationAuthor name used in this publication: X. D. Xueen_US
dc.description.otherinformationRefereed conference paperen_US
dcterms.abstractThe leakage inductance of the spiral winding transformer is examined. Two dimensional leakage field is modeled and leakage field linkage is then obtained to calculate the leakage inductance. The transformer is an air core based with a separation between the primary and secondary. The application is for contactless power conversion.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationCEFC 2006 : the twelfth biennial IEEE Conference on Electromagnetic Field Computation : Miami, Florida, USA, April 30th-May 3rd, 2006, p. 324-
dcterms.issued2006-
dc.identifier.scopus2-s2.0-42749106300-
dc.relation.ispartofbookCEFC 2006 : the twelfth biennial IEEE Conference on Electromagnetic Field Computation : Miami, Florida, USA, April 30th-May 3rd, 2006-
dc.identifier.rosgroupidr28706-
dc.description.ros2005-2006 > Academic research: refereed > Refereed conference paper-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Conference Paper
Files in This Item:
File Description SizeFormat 
Leakage field modeling of spiral winding transformer_06.pdf289.48 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

143
Last Week
1
Last month
Citations as of Apr 14, 2024

Downloads

160
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

1
Last Week
0
Last month
0
Citations as of Apr 19, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.