Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/16606
Title: A comparative study of the performance of different corneal topographers on children with respect to orthokeratology practice
Authors: Chui, WS
Cho, P 
Keywords: Apical radius
Chinese
Corneal topography
Eccentricity
Elevation
Orthokeratology
Issue Date: 2005
Publisher: Lippincott Williams & Wilkins
Source: Optometry and vision science, 2005, v. 82, no. 5, p. 420-427 How to cite?
Journal: Optometry and vision science 
Abstract: Purpose. The purpose of this study was to evaluate and compare the performance of three topographers, Medmont E300, Keratron Scout, and Humphrey Atlas 991, for the measurement of corneal parameters of interest in orthokeratology practice on young children. Methods. Apical radius (R 0), flattest corneal curvature (flat k), eccentricity (e) value, and elevation at 9-mm chord were measured twice on 22 healthy subjects of mean ± standard deviation (SD) age 11.2 ± 2.2 years using the topographers under investigation. Results. The repeatability of the Medmont and Humphrey were good for the measurements of R0 and flat k. The repeatability of the Humphrey was also good for the measurement of e-value. However, for both topographers, the measurement of elevation was not precise enough for orthokeratology empirical lens design. The Keratron showed poor repeatability for all the parameters evaluated. The agreement of the parameters of interest between these instruments was poor. Conclusions. The Medmont and the Humphrey showed good repeatability on children, but the precision of elevation measurements was not good enough to be used for designing empiric orthokeratology lenses on children. The Keratron is not recommended to be used on children in orthokeratology fitting and management. Interinstrumental agreements were significantly different and therefore measurements from different topographers should not be used interchangeably.
URI: http://hdl.handle.net/10397/16606
ISSN: 1040-5488
EISSN: 1538-9235
DOI: 10.1097/01.OPX.0000162642.24885.71
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

16
Last Week
0
Last month
0
Citations as of Aug 20, 2017

WEB OF SCIENCETM
Citations

16
Last Week
0
Last month
0
Citations as of Aug 20, 2017

Page view(s)

25
Last Week
0
Last month
Checked on Aug 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.