Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/1649
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Electrical Engineering-
dc.creatorJun, L-
dc.creatorXu, D-
dc.creatorCheng, KWE-
dc.date.accessioned2014-12-11T08:26:36Z-
dc.date.available2014-12-11T08:26:36Z-
dc.identifier.isbn0-7803-8399-0-
dc.identifier.urihttp://hdl.handle.net/10397/1649-
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.rights© 2004 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.en_US
dc.rightsThis material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.en_US
dc.subjectArraysen_US
dc.subjectEnergy storageen_US
dc.subjectHarmonic analysisen_US
dc.subjectModulationen_US
dc.subjectPhase shiften_US
dc.subjectSwitchingen_US
dc.titleA novel current source converter array with swapping of module control signalen_US
dc.typeConference Paperen_US
dc.description.otherinformationAuthor name used in this publication: K. W. E. Chengen_US
dc.description.otherinformationRefereed conference paperen_US
dcterms.abstractA current source converter array designed for superconducting magnetic energy storage system was investigated. This array is controlled by modulation-signal phase-shifting SPWM method. The DC side current of each converter module of the converter array can balance automatically at the unity power factor, but unbalanced seriously with the decrease of input power factor. In addition, the DC side current unbalancing causes higher distortion of the AC input current. Swapping of the gating signal of each converter module in same row is introduced to average the DC side currents. The harmonics of the AC currents is reduced while the DC side currents are balanced. 2×2 array and 2×4 array are studied in the experiments.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationPESC04 : 2004 IEEE 35th Annual Power Electronics Specialists Conference : June 20-25, 2004, Aachen, Germany : conference proceedings, p. 2817-2821-
dcterms.issued2004-
dc.identifier.scopus2-s2.0-8744260745-
dc.relation.ispartofbookPESC04 : 2004 IEEE 35th Annual Power Electronics Specialists Conference : June 20-25, 2004, Aachen, Germany : conference proceedings-
dc.relation.conferenceIEEE Power Electronics Specialists Conference [PESC]-
dc.identifier.rosgroupidr18730-
dc.description.ros2003-2004 > Academic research: refereed > Refereed conference paper-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Conference Paper
Files in This Item:
File Description SizeFormat 
Current Source Converter Array_04.pdf408.15 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

135
Last Week
2
Last month
Citations as of Apr 21, 2024

Downloads

199
Citations as of Apr 21, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.