Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/15812
Title: Voxel-based approach to generate entire human metacarpal bone with microscopic architecture for finite element analysis
Authors: Tang, CY 
Tsui, CP 
Tang, YM
Wei, L
Wong, CT
Lam, KW
Ip, WY
Lu, WWJ
Pang, MYC 
Keywords: Finite element model
Grayscale intensity threshold
Human metacarpal bone
Micro-computed tomography (micro-CT)
Microscopic architecture
Voxel-based
Issue Date: 2014
Publisher: IOS Press
Source: Bio-medical materials and engineering, 2014, v. 24, no. 2, p. 1469-1484 How to cite?
Journal: Bio-medical materials and engineering 
Abstract: With the development of micro-computed tomography (micro-CT) technology, it is possible to construct three-dimensional (3D) models of human bone without destruction of samples and predict mechanical behavior of bone using finite element analysis (FEA). However, due to large number of elements required for constructing the FE models of entire bone, this demands a substantial computational effort and the analysis usually needs a high level of computer. In this article, a voxel-based approach for generation of FE models of entire bone with microscopic architecture from micro-CT image data is proposed. To enable the FE analyses of entire bone to be run even on a general personal computer, grayscale intensity thresholds were adopted to reduce the amount of elements. Human metacarpal bone (MCP) bone was used as an example for demonstrating the applicability of the proposed method. The micro-CT images of the MCP bone were combined and converted into 3D array of pixels. Dual grayscale intensity threshold parameters were used to distinguish the pixels of bone tissues from those of surrounding soft tissues and improve predictive accuracy for the FE analyses with different sizes of elements. The method of selecting an appropriate value of the second grayscale intensity threshold was also suggested to minimize the area error for the reconstructed cross-sections of a FE structure. Experimental results showed that the entire FE MCP bone with microscopic architecture could be modeled and analyzed on a personal computer with reasonable accuracy.
URI: http://hdl.handle.net/10397/15812
ISSN: 0959-2989
EISSN: 1878-3619
DOI: 10.3233/BME-130951
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page view(s)

62
Last Week
1
Last month
Checked on Aug 21, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.