Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/1379
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Electrical Engineering-
dc.creatorLeung, FHF-
dc.creatorLam, HK-
dc.creatorTam, PKS-
dc.date.accessioned2014-12-11T08:26:23Z-
dc.date.available2014-12-11T08:26:23Z-
dc.identifier.isbn0-7803-4863-X-
dc.identifier.urihttp://hdl.handle.net/10397/1379-
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.rights© 1998 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.en_US
dc.rightsThis material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.en_US
dc.subjectControl system analysisen_US
dc.subjectDigital control systemsen_US
dc.subjectMathematical modelsen_US
dc.subjectMultivariable control systemsen_US
dc.subjectParameter estimationen_US
dc.subjectRobustness (control systems)en_US
dc.subjectSystem stabilityen_US
dc.titleStability and robustness analysis of uncertain multivariable fuzzy digital control systemsen_US
dc.typeConference Paperen_US
dc.description.otherinformationAuthor name used in this publication: F. H. F. Leungen_US
dc.description.otherinformationAuthor name used in this publication: P. K. S. Tamen_US
dcterms.abstractThis paper presents the stability and robustness analysis of digital fuzzy control systems subject to parameter uncertainties. To carry out the analysis, we first describe exactly a digital nonlinear system with parameter uncertainties with a fuzzy plant model. Second, a digital fuzzy controller is proposed to close the feedback loop. Three design approaches are introduced. Based on the resultant fuzzy control system, a stability condition is derived for each design approach. A numerical example is given to show the merits.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationThe 1998 IEEE International Conference on Fuzzy Systems proceedings : IEEE World Congress on Computational Intelligence : May 4-May 9, 1998, Anchorage, Alaska, USA, p. 372-377-
dcterms.issued1998-
dc.identifier.isiWOS:000074668800066-
dc.identifier.scopus2-s2.0-0031628078-
dc.relation.ispartofbookThe 1998 IEEE International Conference on Fuzzy Systems proceedings : IEEE World Congress on Computational Intelligence : May 4-May 9, 1998, Anchorage, Alaska, USA-
dc.relation.conferenceIEEE International Conference on Fuzzy Systems [FUZZ]-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Conference Paper
Files in This Item:
File Description SizeFormat 
Uncertain multivariable fuzzy digital_98.pdf375.92 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

129
Last Week
1
Last month
Citations as of Mar 24, 2024

Downloads

171
Citations as of Mar 24, 2024

SCOPUSTM   
Citations

1
Last Week
0
Last month
0
Citations as of Mar 22, 2024

WEB OF SCIENCETM
Citations

1
Last Week
0
Last month
0
Citations as of Mar 28, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.