Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/13230
Title: Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT
Authors: Leung, CKS
Cheung, CYL
Li, H
Dorairaj, S
Yiu, CKF 
Wong, AL
Liebmann, J
Ritch, R
Weinreb, R
Lam, DSC
Issue Date: 2007
Publisher: Association for Research in Vision and Ophthalmology
Source: Investigative ophthalmology and visual science, 2007, v. 48, no. 9, p. 4116-4122 How to cite?
Journal: Investigative ophthalmology and visual science 
Abstract: PURPOSE. To describe the use of anterior segment optical coherence tomography (OCT) in studying the dynamic dark-light changes of the anterior chamber angle. METHODS. Thirty-seven normal subjects with open angles on dark-room gonioscopy and 18 subjects with narrow angles were analyzed. The dynamic dark-light changes of the anterior-chamber angle were captured with real-time video recording. The angle opening distance (AOD500) and trabecular iris space area (TISA500) of the nasal angle and the pupil diameter in each of the representative serial images were measured. Linear regression analysis was performed to investigate the association between AOD500/TISA500 and pupil diameter. Demographic and biometry measurements associated with the AOD difference (AOD500 (light) - AOD500 (dark)) and TISA difference (TISA500 (light) - TISA500 (dark)) were analyzed with univariate and multivariate regression models. RESULTS. The AOD500/TLSA500 measured in the light in the open-angle and the narrow-angle groups were 694 ± 330 μm/0.24 ± 0.10 mm 2 and 265 ±78 μm/0.10 ± 0.03 mm 2, respectively. These values were significantly greater than the AOD500/TISA500 measured in the dark (492 ± 265 μm/0.16 ± 0.08 mm 2 and 119 ± 82 μm/0.05 ± 0.04 mm 2, respectively, all with P < 0.001). The ranges of the AOD/TISA difference were 13 to 817 μm/0.011 to 0.154 mm 2, with an average of 180 μm/0.073 mm 2. Multivariate regression analysis identified a positive correlation between anterior chamber depth and the AOD/TISA difference. Fifty eyes showed significant correlations between AOD/TISA and pupil diameter, whereas one eye showed no association. Four eyes in the narrow angle group developed appositional angle closure in the dark. CONCLUSIONS. The dynamic dark-light changes of the anterior chamber angle can be imaged and analyzed with anterior segment OCT. Although the angle width generally decreased linearly with increasing pupil diameter, the differences of the angle width measured in the dark and in the light varied substantially among individuals.
URI: http://hdl.handle.net/10397/13230
ISSN: 0146-0404
EISSN: 1552-5783
DOI: 10.1167/iovs.07-0010
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

55
Last Week
0
Last month
2
Citations as of Sep 22, 2017

WEB OF SCIENCETM
Citations

52
Last Week
0
Last month
1
Citations as of Sep 22, 2017

Page view(s)

44
Last Week
5
Last month
Checked on Sep 25, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.