Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/12436
Title: Helical tomotherapy of nasopharyngeal carcinoma—any advantages over conventional intensity-modulated radiotherapy?
Authors: Wu, WV 
Mui, WL
Fung, WK
Keywords: Nasopharyngeal carcinoma
Helical tomotherapy
Intensity modulated radiotherapy
Dosimetric comparison
Issue Date: 2010
Source: Medical dosimetry, 2010, v. 35, no. 2, p. 122-127 How to cite?
Journal: Medical dosimetry 
Abstract: Helical tomotherapy uses different planning algorithm and dose delivery method from the linear accelerator (linac)-based intensity-modulated radiotherapy (IMRT). This study compared the dosimetric outcomes between the tomotherapy plans and conventional linac-based IMRT plans in the treatment of nasopharyngeal carcinoma (NPC). Fifteen stage II–III cancer (American Joint Committee on Cancer) NPC patients treated by tomotherapy were conveniently recruited. Apart from the tomotherapy plans, a 7-field 6-MV photon conventional IMRT plan was computed for each patient with the same CT dataset and reference from the dose constraints and target dose prescriptions of the tomotherapy plans using the XiO treatment planning system. Average values of the dose parameters including the conformity index (CI), homogeneity index (HI), maximum and minimum doses of the target volumes, and the maximum and mean doses of the organs at risk (OAR) were compared between the two treatment methods. Better dose coverage of the planning target volume (PTV) was demonstrated in the tomotherapy plans, in which the differences in the maximum and mean doses reached statistical significance (p < 0.05). Besides, the CI of the tomotherapy plans were significantly higher than the conventional linac-based plans for the nasopharynx PTV (NP-PTV) and neck lymphatics PTV (LN-PTV) (p = 0.017 and 0.010, respectively). The HI was significantly smaller in both NP-PTV and LN-PTV (p = 0.024 and < 0.001, respectively). Among the OAR, the brain stem and spinal cord doses in the tomotherapy plans were lower than that of the conventional IMRT plans. However, the doses to the other OAR did not show significant dosimetric differences. In the treatment of nasopharyngeal carcinoma, tomotherapy plans were superior to the 7-field conventional IMRT plans in PTV dose conformity and homogeneity and the sparing of the brain stem and spinal cord. However, no significant advantages were observed for the rest of the OAR.
URI: http://hdl.handle.net/10397/12436
ISSN: 0958-3947
DOI: 10.1016/j.meddos.2009.04.001
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

3
Last Week
0
Last month
Citations as of Nov 17, 2017

WEB OF SCIENCETM
Citations

2
Last Week
0
Last month
0
Citations as of Nov 18, 2017

Page view(s)

66
Last Week
4
Last month
Checked on Nov 20, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.