Title: Multi-type sensor placement for multi-scale response reconstruction
Authors: Zhu, S 
Zhang, XH
Xu, YL 
Zhan, S
Keywords: Kalman filter
Multi-scale monitoring
Multi-scale response reconstruction
Multi-type sensors
Sensor location selection
Issue Date: 2013
Publisher: Multi-Science
Source: Advances in structural engineering, 2013, v. 16, no. 10, p. 1779-1797 How to cite?
Journal: Advances in structural engineering 
Abstract: Although various types of sensors are now available to monitor a structure, measurements are usually obtained in only a few locations numbering less than the total degrees of freedom (DOFs) of the structure. The lack of structural responses of the structure at all its critical areas may hamper the effectiveness of structural monitoring. Therefore, multi-scale response reconstruction at those key structural locations where sensors are not available is essential to fully achieving the structural monitoring objectives. This paper addresses a problem of placing multi-type sensors in a structure with the objective of best reconstruction of structural responses. The types of sensors include accelerometers, displacement and strain measurement sensors, all of which are widely used in civil engineering structures. The number and locations of the three types of sensors are determined aiming to best possibly reconstruct the strain, displacement and acceleration responses, in which the Kalman filter algorithm is employed. By minimizing the overall reconstruction error variance at the locations of interest and maintaining reconstruction errors to a desired target level, the initial set of candidate sensor locations is reduced to a smaller set. The key multi-scale structural responses are reconstructed from the fusion of limited multi-type sensor data information. A simply-supported overhanging steel beam is investigated as a sample case in numerical and experimental study to investigate the effectiveness and accuracy of the presented approach. The good response reconstruction results clearly demonstrate the effectiveness of the proposed optimal placement method for multi-type sensors.
URI: http://hdl.handle.net/10397/12327
ISSN: 1369-4332
EISSN: 2048-4011
DOI: 10.1260/1369-4332.16.10.1779
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

6
Last Week
0
Last month
0
Citations as of Aug 19, 2017

WEB OF SCIENCETM
Citations

6
Last Week
0
Last month
0
Citations as of Aug 13, 2017

Page view(s)

36
Last Week
2
Last month
Checked on Aug 14, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.