Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/11296
Title: Modelling of NOx emissions in tangential coal fired boiler part 1 - conventional boiler
Authors: Lee, CL
Leung, CW 
Cheung, CS 
Issue Date: 2011
Source: Journal of the Energy Institute, 2011, v. 84, no. 1, p. 13-20
Abstract: In a power generation unit, the dynamic nature of a tangential coal fired boiler integrating with the complex NOx formation mechanism leads to a major difficulty for the prediction of NOx emission levels under different operating conditions. This paper suggests a simple method to tackle the problem. A model was developed by considering NOx formation mechanisms, burner configuration and air flow distribution. With the aid of the data obtained from operation, an empirical equation was developed for the prediction of NOx emission levels of a conventional tangential coal fired boiler that is not equipped with any de‐NOx facility.
Keywords: Coal fired boiler
Nitrogen oxides
Pollution control
Publisher: Maney
Journal: Journal of the Energy Institute 
ISSN: 1743-9671
DOI: 10.1179/014426011X12901840102409
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record