Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/11133
Title: A retrospective survey on elevator evacuation of supertall buildings under fires
Authors: Chow, WK 
Issue Date: 2006
Publisher: Baywood Publishing Co. Inc.
Source: Journal of applied fire science, 2006, v. 16, no. 4, p. 315-327 How to cite?
Journal: Journal of applied fire science 
Abstract: Many supertall buildings up to 500mare constructed in the Far East. Big fires in such tall buildings during office hours are a nightmare to firemen. Lots of combustibles might be stored in crowded offices with glass facades. Big fires in tall buildings have been observed many times all over the world. Evacuation is identified as the key problem. Full evacuation is impossible for supertall buildings, taking over 2 hours even in a normal fire drill with good orders. Refuge floors and staged evacuation might be a solution. However, there are queries on whether refuge floors are safe under big post-flashover fires after the World Trade Center tragedy. Elevators are proposed for selective use in the case of fire for accelerating the evacuation process. Studies on elevator evacuation for tall buildings of normal height started over 20 years ago in North America. Results on smoke movement and its management in tall buildings of normal height, human behavior and orderly evacuation, evacuation times modeling, integration with refuge evacuation, and water damage were reported. None of those works related specifically to supertall buildings under big fires. In fact, the use of elevators is included in the evacuation strategy for several supertall buildings in Hong Kong. The elevator systems, however, are not demonstrated to be safe in a fire, leading to deep concern from local fire authority. There is an urgent need to evaluate performance of such existing elevator systems for emergency evacuation in supertall buildings. Active fire protection systems should be upgraded if necessary. In this article, concerns of elevator evacuation are summarized. Points of consideration in designing safe elevator systems in supertall buildings under big fires will be discussed with reference to the literature works.
URI: http://hdl.handle.net/10397/11133
ISSN: 1044-4300
EISSN: 1541-4183
DOI: 10.2190/AF.16.4.c
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

4
Last Week
0
Last month
0
Citations as of Nov 10, 2017

Page view(s)

43
Last Week
1
Last month
Checked on Nov 12, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.