Title: Optimum parameters of tuned liquid column damper for suppressing pitching vibration of an undamped structure
Authors: Xue, SD
Ko, JM 
Xu, YL 
Issue Date: 2000
Publisher: Academic Press
Source: Journal of sound and vibration, 2000, v. 235, no. 4, p. 639-653 How to cite?
Journal: Journal of sound and vibration 
Abstract: In order to evaluate the control performance of the tuned liquid column damper in suppressing pitching vibration of structures, an optimal parametric study of the damper is carried out for an undamped structure. The structure is assumed to be subjected to harmonic excitation in the analysis. The optimum tuning ratio (or the optimum liquid length) and the optimum head loss coefficient of the damper are determined using Den Hartog's method. The analytical formulas of the optimum TLCD parameters for the undamped structure are derived. The optimum peak amplitudes for the structure and the liquid are also obtained. Based on the developed analytical formulas, the practical solution procedures for finding the optimum parameters are proposed. The presented example indicates that the optimum TLCD parameters can be easily calculated from the developed formulas. With the help of this study, the understanding of TLCD behavior with respect to its optimum parameters is enhanced.
URI: http://hdl.handle.net/10397/10774
ISSN: 0022-460X
EISSN: 1095-8568
DOI: 10.1006/jsvi.2000.2947
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

11
Last Week
0
Last month
0
Citations as of Nov 8, 2017

WEB OF SCIENCETM
Citations

10
Last Week
0
Last month
0
Citations as of Nov 17, 2017

Page view(s)

41
Last Week
0
Last month
Checked on Nov 19, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.