Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/10758
Title: Wavelength and power monitoring of DWDM systems using scanning F-P filter calibrated with a F-P laser
Authors: Chung, WH
Tam, HY 
Demokan, MS
Wai, PKA 
Lu, C
Keywords: Optical power monitoring
Wavelength monitoring
WDM applications
Issue Date: 2002
Publisher: North-Holland
Source: Optics communications, 2002, v. 210, no. 3-6, p. 219-224 How to cite?
Journal: Optics communications 
Abstract: The wavelength and power monitoring of dense wavelength division multiplexing (DWDM) was studied by using Fabry-Perot filters. The biasing of the Fabry-Perot laser around the threshold region minimized the wavelength drift due to the current fluctuations. The wavelength and power monitoring of eight channels spaced 0.8 nm apart showed an accuracy of ±0.01 nm and 0.2 dB respectively.
URI: http://hdl.handle.net/10397/10758
ISSN: 0030-4018
EISSN: 1873-0310
DOI: 10.1016/S0030-4018(02)01804-7