Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/10208
Title: A semi-quantitative approach to compare high-sensitivity power doppler sonography and conventional power doppler sonography in the assessment of thyroid vascularity
Authors: Ying, M 
Ng, DKS
Yung, DMC
Lee, EST
Issue Date: 2009
Publisher: Mary Ann Liebert Inc
Source: Thyroid, 2009, v. 19, no. 11, p. 1265-1269 How to cite?
Journal: Thyroid 
Abstract: Background: Ultrasound is a useful imaging tool in the assessment of thyroid glands, and Doppler ultrasound helps in the evaluation of thyroid vascularity. This study was undertaken to evaluate the difference in the thyroid vascularity demonstrated on the state-of-the-art high-sensitivity power Doppler sonography (HSPDS) and the conventional power Doppler sonography (PDS), and to investigate the feasibility of using a customized algorithm with image-processing software for semi-quantitative assessment of thyroid vascularity. Methods: A total of 25 healthy volunteers were included in the study, and each subject had two thyroid ultrasound examinations with HSPDS and PDS, respectively. High sensitivity and conventional power Doppler sonograms of the thyroid glands were taken and recorded. To evaluate the vascularity of thyroid lobes quantitatively, a customized algorithm using the software Matlab ® was developed and used to analyze the ultrasound images. The vascularity of thyroid lobe (i.e., region of interest, ROI) was expressed as the vascular index (VI), which is the ratio of the number of color pixels to the total number of pixels within the ROI. Results: Results showed that thyroid vascularity was detected in all thyroid lobes on both HSPDS and PDS. The mean VI of the thyroid lobes on HSPDS (right lobe, 0.31±0.08; left lobe, 0.32±0.07) was significantly higher than on PDS (right lobe, 0.18±0.09; left lobe, 0.16±0.08) (p<0.05). There was no significant difference in the VI between the right and left thyroid lobes (p>0.05). On HSPDS, 96% of the thyroid lobes showed a VI<0.5, while 96% of thyroid lobes had a VI<0.3 on PDS. Conclusions: HSPDS is more sensitive than PDS in the detection of thyroid vascularity. The developed algorithm can quantify the color pixels on power Doppler sonograms, which is useful for objective assessment of thyroid vascularity.
URI: http://hdl.handle.net/10397/10208
DOI: 10.1089/thy.2009.0221
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

10
Last Week
0
Last month
0
Citations as of Aug 12, 2017

WEB OF SCIENCETM
Citations

9
Last Week
0
Last month
0
Citations as of Aug 12, 2017

Page view(s)

29
Last Week
4
Last month
Checked on Aug 14, 2017

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.